Filter for 3-phase inverter with capacity 95kA

Product code: FI-200
Price: Vui lòng liên hệ

Filter for 3-phase inverter with capacity 95kA with rated current 2000A

CALL TO ORDER
Mr.Trí
Điện thoại: 0906 564 000


Ms. Trinh
Điện thoại: 09 8968 2232
Filter for 3-phase inverter with capacity 95kA with rated current 200A

Product Information

The FT330 series is designed based on the frequency domain properties of the inverter's input at the inverter's inlet and on other digital devices. The three-stage filter design uses a special magnetic material to ensure high impedance in the wide frequency range. The frequency converter around the normal operation of electronic devices to address the large interference of inverter interference. 250A on the use of co-routing, with more uniform international design standards, convenient and secure customer connection.

  • Good performance of suppressing common mode and differential mode interference, effectively suppress the conducted interference from inverter.
  • Various connection ways, terminal block terminals(with or without arcing shield) available
  • Suited for working place with strict requirement of environment
  • Safety approval:ϹЄ

 

Manual instruction

Filter guide Filter storage and operating environment Power filters are not exposed or exposed to rain, should be stored in the air, the maximum relative humidity of the air does not exceed the heat. ambient temperature -30 ° C to +65 ° C 90% (air temperature 20 ℃ ± 5 ℃), non-corrosive liquid, storage gas.

Filter settings:

Filter installation location should be selected at the source entrance, shortening the length of the line into the frame, reducing the radiation interference. Filter the input and output lines: neither cross nor tie. The filter housing must be grounded in a large area, the ground wire should be as short as possible when connected to other equipment. If the output of the filter is a bolt, the user must use two bolts to tighten the nut when wiring to avoid internal line changes due to bolt rotation caused by short circuit and reduce FEng effect. The snake screw when first using the refusal of an early stage of the widow, then wrench the nut with a wrench - otherwise it could damage the XB Terminal filter - another drag.

Weight:11000g

Product size:

 

Customer Support
Sales Support 1
Ms. Trinh
Call 09 8968 2232
Zalo 09 8968 2232
Facebook Messenger 09 8968 2232
Viber 09 8968 2232
Sales Support 2
Tri (Jhonny)
0906 564 000
Call 0906564000
Zalo 0906564000
Facebook Messenger 0906564000
Viber 0906564000
Visitors
867
Online
101

LIVE SUPPORTCHAT FACEBOOK